Sdc 491 EMERGENCY DOOR RELEASE Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
INSTALLATION INSTRUCTIONS
492 PULL STATION EMERGENCY DOOR RELEASE
P:\INSTALLATION INST\Accessories\INST-492.vsd REV A Page 1 07-08
An
y suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
INSTALLERS NOTE;
The station is supplied with the glass rod removed. It is
recommended that the station be activated and tested prior
to installation of the glass rod.
Glass Rod and Hardware are shipped in the station box.
REPLACEMENT OF GLASS ROD;
Use an Allen wrench to open front cover of station. Remove
the glass debris from broken rod, then reset T-Handle to the
normal position.
To replace Glass Rod, insert one end of Rod under Spring
Tab. Then, with one finger lift other end of Spring Tab
allowing Glass Rod to slip into place.
TO CLOSE STATION;
ELECTRICAL SPECIFICATIONS;
Switch Contacts: DPDT 10A @ 125vac
Buzzer: 12/24vdc @ 10/20ma
51
62
73
84
N/O
N/C
N/O
N/C
Terminal
Block A
Terminal
Block B
Micro
Switch B
Micro
Switch A
Buzzer Power
Supply
12/24vdc
-
+
OPTIONAL;
Back box model #492-BB available for
surface mount
Replacement Glass Rod #492-GL4
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, CA 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
Seitenansicht 1
1 2

Kommentare zu diesen Handbüchern

Keine Kommentare