P:\INSTALLATION INST\Power Supplies\INST-602RF.vsd Rev F 01-12
SPECIAL APPLICATIONS POWER SUPPLY
INSTALLATION INSTRUCTIONS
MODEL 602RF
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, Ca. 93012
(805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
POWER SUPPLY SPECIFICATIONS
Input Voltage: 115/230 VAC @ 60hz
Input Current: 0.8 amps Max.
Output Voltage: 12/24VDC (Special Applications)
Burglary Use:
Output Voltage Ranges:
12 V Operation: 9.2 – 12.0 VDC
24 V Operation: 21.2 – 24.0 VDC
Output Current: 1.0 amps
Ripple Voltage: 0.05 Volts Max
Battery Charger Max Current: 0.25 amps
Maximum recommended battery size: 4ah
(Replace batteries every three years)
To determine standby battery capacity, refer to
Batter Discharge table (INST-BDT).
Compatible UL listed Fire Devices:
Smoke detector manufactured by ESL, Model 521B,
521BXT with Model 506 module.
Suitable Uses:
Electric Lock Power Supply
Access Control Power Supply
Burglar Alarm System Power Supply
Fire Protective Signaling Service
NOT INTENDED TO POWER A LOCAL
BURGLAR ALARM INDICATING DEVICE.
TEST UNIT YEARLY
COMPONENT LOCATIONS
STANDARD BOX
POWER
SUPPLY
BOARD
CONTROL
MODULE
CONTROL
MODULE
BATTERY 1
4ah
BATTERY 2
4ah
MAIN SYSTEM ON-OFF
OR
FIRE PANEL CONNECTION
Fire Panel
Contact (N/C)
Master ON/OFF
Switch (N/C)
+
_
C
Figure C
C
+
_
Min. Switch
OR
Contact Ratings
100mA @ 30vdc
MODEL 602RF
AC Voltage
Input
AC Voltage
Input
Manuel
Reset
Battery Input
Terminals
Voltage Output
Terminals
System
Status LED
Yellow = System OK
Red = No AC Input
Green = No DC Output
12VDC
+
_
12VDC
+
_
JUMPER SET
FOR 24 VDC
+
-
JUMPER SET
FOR 12 VDC
12VDC
+
_
+
-
NOTE:
Power limited cable
must maintain a 1/4”
or more spacing from
battery cables or
primary power wires.
_
Battery
+
Power limited
Class 2 output
602RF
High voltage
Input
+ -
+ -
C
Wire Routing
12 Volt Mode Battery
Connections
24 Volt Mode Battery
Connections
Seitenansicht 0